User Interface Project: TestEliwellUI

Last update: 11/07/2017 - 15:09:33

Project infos:

Number of pages: 6
Languages:
- russo
- BaseLanguage
Start page: Page6_Icons

Page Infos:

Page6_Icons
Page6_Icons.bmp
Edits: 7
Edit_12 Min: 0 Max: 59 Var: @PLC.sysClock_seconds
Edit_13 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Edit_14 Min: 0 Max: 59 Var: @PLC.sysClock_minutes
Edit_17 Min: 1 Max: 31 Var: @PLC.sysClock_daymonth
Edit_19 Min: 1 Max: 12 Var: @PLC.sysClock_month
Edit_21 Min: 0 Max: 99 Var: @PLC.sysClock_year
Edit_22 Min: 0 Max: 6 Var: @PLC.sysClock_dayweek
Page5_Set
Page5_Set.bmp
Progresses: 1
Progress_30 Min: 0 Max: $PagNumber Var: $PagIndex
Edits: 13
Edit_1 Min: * Max: * Var: #Set_1(0)
Edit_12 Min: 0 Max: 59 Var: @PLC.sysClock_seconds
Edit_13 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Edit_14 Min: 0 Max: 59 Var: @PLC.sysClock_minutes
Edit_17 Min: 1 Max: 31 Var: @PLC.sysClock_daymonth
Edit_19 Min: 1 Max: 12 Var: @PLC.sysClock_month
Edit_21 Min: 0 Max: 99 Var: @PLC.sysClock_year
Edit_22 Min: 0 Max: 6 Var: @PLC.sysClock_dayweek
Edit_24 Min: * Max: * Var: #Set_1(1)
Edit_26 Min: * Max: * Var: #Set_1(2)
Edit_27 Min: * Max: * Var: $PagIndex
Edit_28 Min: * Max: * Var: $PagNumber
Edit_36 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Page4
Page4.bmp
Edits: 11
Edit_1 Min: -32765 Max: * Var: sysSensorNTC
Edit_6 Min: 100 Max: 300 Var: @PLC.SetPoint
Edit_9 Min: -32765 Max: * Var: sysSensorRH
Edit_11 Min: -32765 Max: * Var: sysSensorPIR
Edit_16 Min: 0 Max: 59 Var: @PLC.sysClock_seconds
Edit_17 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Edit_18 Min: 0 Max: 59 Var: @PLC.sysClock_minutes
Edit_19 Min: 1 Max: 31 Var: @PLC.sysClock_daymonth
Edit_20 Min: 1 Max: 12 Var: @PLC.sysClock_month
Edit_21 Min: 0 Max: 99 Var: @PLC.sysClock_year
Edit_22 Min: 0 Max: 6 Var: @PLC.sysClock_dayweek
Page3
Page3.bmp
Edits: 11
Edit_1 Min: -32765 Max: * Var: sysSensorNTC
Edit_6 Min: 100 Max: 300 Var: @PLC.SetPoint
Edit_9 Min: -32765 Max: * Var: sysSensorRH
Edit_11 Min: -32765 Max: * Var: sysSensorPIR
Edit_16 Min: 0 Max: 59 Var: @PLC.sysClock_seconds
Edit_17 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Edit_18 Min: 0 Max: 59 Var: @PLC.sysClock_minutes
Edit_19 Min: 1 Max: 31 Var: @PLC.sysClock_daymonth
Edit_20 Min: 1 Max: 12 Var: @PLC.sysClock_month
Edit_21 Min: 0 Max: 99 Var: @PLC.sysClock_year
Edit_22 Min: 0 Max: 6 Var: @PLC.sysClock_dayweek
Page2
Page2.bmp
Edits: 11
Edit_1 Min: -32765 Max: * Var: sysSensorNTC
Edit_6 Min: 100 Max: 300 Var: @PLC.SetPoint
Edit_9 Min: -32765 Max: * Var: sysSensorRH
Edit_11 Min: -32765 Max: * Var: sysSensorPIR
Edit_16 Min: 0 Max: 59 Var: @PLC.sysClock_seconds
Edit_17 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Edit_18 Min: 0 Max: 59 Var: @PLC.sysClock_minutes
Edit_19 Min: 1 Max: 31 Var: @PLC.sysClock_daymonth
Edit_20 Min: 1 Max: 12 Var: @PLC.sysClock_month
Edit_21 Min: 0 Max: 99 Var: @PLC.sysClock_year
Edit_22 Min: 0 Max: 6 Var: @PLC.sysClock_dayweek
Page1
Page1.bmp
Edits: 11
Edit_1 Min: -32765 Max: * Var: sysSensorNTC
Edit_6 Min: 100 Max: 300 Var: @PLC.SetPoint
Edit_9 Min: -32765 Max: * Var: sysSensorRH
Edit_11 Min: -32765 Max: * Var: sysSensorPIR
Edit_12 Min: 0 Max: 59 Var: @PLC.sysClock_seconds
Edit_13 Min: 0 Max: 23 Var: @PLC.sysClock_hours
Edit_14 Min: 0 Max: 59 Var: @PLC.sysClock_minutes
Edit_17 Min: 1 Max: 31 Var: @PLC.sysClock_daymonth
Edit_19 Min: 1 Max: 12 Var: @PLC.sysClock_month
Edit_21 Min: 0 Max: 99 Var: @PLC.sysClock_year
Edit_22 Min: 0 Max: 6 Var: @PLC.sysClock_dayweek